How wet can the chips be?
The PelleTech boilers handle wood chips with up to 40 % moisture content. Multiauto handles 30–40 %, depending on the fuel.
Moisture content of the fuel, up to
The wetter the chips, the lower the output and the more fuel is used – some of the heat goes into boiling off the water. Dry chips under cover give more heat. So plan the fuel logistics and the ventilation of the store; a supporting floor in the chip store allows ventilation for drying.
For really wet chips there is the Biotherm burner, which burns extremely moist wood chips – and horse manure with up to 60 % moisture content.
What size should the chips be?
Chip size is now specified as P16S and P31S, formerly G50 – G50+ in the brochures. These are the chips the boilers are made for.
Larger fractions also work, with larger screws: from 38 kW, Multiauto is available with a 150 mm stoker screw, and industrial boilers can have feed screws of up to 180 mm. The BU wood chip burner handles chips up to P45S. The rotary valve in Multiauto cuts light material longer than 16 cm. We plan coarser material together with you.
- Chip size
- P16S · P31S (G50+)
- Moisture content, PelleTech boilers
- Up to 40 %
- Stoker screw, Multiauto from 38 kW
- 150 mm
- Feed screw, industrial boilers
- Up to 180 mm
- BU wood chip burner
- Chips up to P45S
- BU, ignition
- Up to W50 moisture content
The grate makes the difference.
That the boilers handle wet chips and chips with bark is largely down to the moving stepped grate. It moves during operation, breaks up the bed and cleans itself continuously. A fixed grate limits the fuels that can be burned.