The fuel moves while it burns.
On a stepped grate, the fuel lies on rows of grate elements that move. The chips dry, ignite and burn out as they are carried forward, step by step, until only ash remains.
Because the bed is broken up all the time, the air reaches the fuel, and slag and clogging are prevented. The ash is carried away during operation, so the boiler never has to stop for cleaning.

Stepped grate or tipping grate?
Many smaller boilers have a fixed grate that tips out the ash at regular intervals. The difference shows when the chips are wet, contain bark or are of poorer quality.
| Stepped grate | Tipping grate | |
|---|---|---|
| Operation | The boiler never has to stop for cleaning. | Stops to tip out the ash. |
| Combustion | Steady, even with wetter fuels and chips with bark. | Output drops as bark, hard-to-burn material or impurities build up. |
| Cleaning | Automatic and continuous. | Frequent cleaning, with starts and stops and a risk of sintering. |
The grate in our boilers.
All the PelleTech boilers we sell have a moving grate. The design differs with the size of the boiler and the fuel.
- Multiauto · 20–200 kW
- High-chromium cast-iron grate elements that clean themselves continuously.
- IDRO · 200 kW–4.6 MW
- Moving stepped grate with a drying zone and combustion zones. The bars move back and forth, and slightly up and down, breaking up the bed – with no risk of sintering.
- AERO 150–500 · hot air
- Moving stepped grate of cast iron, with seven levels. Speed, feed and air are controlled according to the moisture content of the fuel.
- BU · wood chip burner
- High-chromium cast-steel grate bars that move along two axes and prevent slag and clogging.